Partial Discharge Test Equipment For Power Transformer Testing
Partial Discharge Test Equipment For Power Transformer Testing
Partial Discharge Test Equipment For Power Transformer Testing
Partial Discharge Test Equipment For Power Transformer Testing
Partial Discharge Test Equipment For Power Transformer Testing
Partial Discharge Test Equipment For Power Transformer Testing

Partial Discharge Test Equipment For Power Transformer Testing

Price 10000 USD ($)/ Set

MOQ : 1 Unit

Partial Discharge Test Equipment For Power Transformer Testing Specification

  • Load Loss
  • Low, <2%
  • Cooling Type
  • Oil Cooled or Air Cooled
  • Dimension (L*W*H)
  • 700 mm x 400 mm x 600 mm (Approx.)
  • Rated Voltage
  • Up to 100 kV
  • High Voltage
  • Up to 150 kV
  • Capacity
  • 5 kVA 1000 kVA
  • Voltage Booster Type
  • Automatic
  • Low Voltage
  • 220 V to 1100 V
  • Coil Material
  • Copper
  • Operating Temperature
  • -10C to +50C
  • Standard
  • IEC 60270, IS 8437
  • Product Type
  • Partial Discharge Test Equipment
  • Material
  • High Grade Electrical Insulation Material and Metallic Enclosure
  • Output
  • Digital Display, Analog Output Option
  • Frequency (MHz)
  • Standard range: 0.1 MHz 10 MHz
  • Efficiency
  • High, >98%
  • Phase
  • Three Phase
  • Usage
  • Partial Discharge Testing of Power Transformers
  • Coil Structure
  • Layer or Winded
  • Coil Number
  • Multiple Coils
  • Power Scope
  • Up to 2500 kVA
  • Weight
  • Approx. 45 kg 75 kg
  • Test Method
  • On-site or Laboratory PD Measurement
  • Mobility
  • Portable, Wheeled Trolley Design
  • Safety Features
  • Emergency Shutoff, Overload Protection
  • Detection Sensitivity
  • <2 pC
  • Calibration
  • Automatic and Manual Modes
  • Data Storage
  • Internal Memory with USB Export
  • Accessories
  • BNC Cables, HV Coupling Capacitor, Test Leads
  • Input Power Supply
  • 230 V AC, 50/60 Hz
  • Signal Processing
  • Advanced Noise Filtering and Digital Signal Processing
  • Display Type
  • TFT Touchscreen, LCD Digital Readout
  • Connector Type
  • Standard BNC and HV Connectors
 

Partial Discharge Test Equipment For Power Transformer Testing Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 60 Days
 

About Partial Discharge Test Equipment For Power Transformer Testing

Partial Discharge Testing System

Description  : This system is used for measuring partial discharge of transformer, motor, instrument transformer, cable, GIS, switch and arrester, etc. The system has multi channel measuring function which allows measuring several test or several points. This method can be successfully used for big transformers and transformer substation.

Main components

  • No partial discharge transformer
  • Partial discharge measuring instrument
  • Isolation low pass filter
  • Coupling capacitor
  • Current limiting resistance
  • Control panel
  • Frequency 50, 100, 150, 200, 400Hz
  • 3dB  fL  10x20x40KHZ optional
  • 3dB  fH  80x200x300KHZ optional
  • Rough adjustment 6 range 20   1dB fine tuning range >20dB



Advanced Signal Processing for Accurate Results

Equipped with state-of-the-art digital signal processing and advanced noise filtering, this test equipment ensures accurate readings even in environments with high electrical noise. This degree of sensitivity, detecting discharges as low as 2 pC, enables early identification of potential insulation faults, thereby minimizing transformer failure risk.


Designed for Operator Safety and Convenience

User safety is prioritized with features like emergency shutoff and overload protection. The units portability, thanks to its wheeled trolley design and robust metallic enclosure, facilitates on-site transportation and installation, while clear digital and analog outputs make data easy to interpret.


User-Friendly Operation and Comprehensive Data Management

The intuitive TFT touchscreen interface and LCD readout support straightforward operation. Internal memory, coupled with USB export, ensures that measurement data can be conveniently stored and analyzed, supporting both rapid on-site troubleshooting and detailed laboratory analysis.

FAQs of Partial Discharge Test Equipment For Power Transformer Testing:


Q: How is partial discharge detected using this equipment?

A: Partial discharge is detected by connecting the instrument to a power transformer via high-voltage (HV) coupling capacitors and BNC cables. The advanced digital signal processing algorithms filter out noise, allowing the device to accurately measure even very small discharges, down to less than 2 pC, as per IEC 60270 methodology.

Q: What are the main benefits of using this PD test equipment for transformer testing?

A: The equipment offers high sensitivity for early fault detection, comprehensive safety overlays (emergency shutoff, overload protection), reliable data integrity with internal memory and USB export, and portability through its wheeled trolley design. These features help reduce transformer failure risk, supporting cost-effective maintenance and greater operational assurance.

Q: When and where should partial discharge testing be performed?

A: Partial discharge testing should be conducted during routine maintenance, pre-commissioning, and whenever abnormal transformer behavior is observed. The portable nature of the equipment allows use both on-site at substations and in controlled laboratory environments, adapting to varying operational needs.

Q: What types of transformers can this equipment test, and what are its capacity limits?

A: This PD test equipment is suitable for layer or winded coil power transformers with three-phase configurations. It supports units up to 2500 kVA, rated voltages of up to 100 kV (primary side), and high voltages up to 150 kV. The frequency operating range is 0.1 MHz to 10 MHz.

Q: How do users manage and export test data from the equipment?

A: Measurement data is automatically saved in the devices internal memory. Users can easily export records via the integrated USB port, facilitating data review, sharing, or more detailed analysis on external computing platforms.

Q: What safety features are integrated into this equipment?

A: Safety features include an emergency shutoff function and automatic overload protection, minimizing risk to operators and connected equipment. The enclosure uses high-grade electrical insulation and metal to further ensure user and asset security during operation.

Q: What accessories come supplied with the PD test kit, and how do they enhance usability?

A: The kit includes BNC cables, high-voltage coupling capacitors, and test leads. These accessories enable flexible testing setups and ensure secure, reliable connections between the device and transformers, enhancing both safety and efficiency in operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transformer Testing Equipment Category

Transformer Winding Resistance Ohmmeter

Transformer Winding Resistance Ohmmeter

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Material : High impact ABS plastic housing

High Voltage : Applicable to high voltage windings

Product Type : Other, Digital Winding Resistance Ohmmeter

Low Voltage : Applicable to low voltage windings

Electrical Silicon Steel Iron Loss Tester

Electrical Silicon Steel Iron Loss Tester

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Material : Silicon Steel

High Voltage : Up to 500V

Product Type : Other, Iron Loss Tester

Low Voltage : 0100V Adjustable

Electrical Silicon Steel Iron Loss Tester

Electrical Silicon Steel Iron Loss Tester

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Material : Silicon Steel

High Voltage : 500V (Test capacity)

Product Type : Other, Iron Loss Tester

Low Voltage : 0250V/0500V Adjustable

Automatic Integrated Test System For Testing Power Transformer

Automatic Integrated Test System For Testing Power Transformer

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Material : Mild Steel

High Voltage : Up to 330 kV

Product Type : Other, Automatic Integrated Test System

Low Voltage : Up to 35 kV



Back to top