Transformer capacitance & dissipation factor measuring bridge
Transformer capacitance & dissipation factor measuring bridge

Transformer capacitance & dissipation factor measuring bridge

Price 10000 USD ($)/ Set

MOQ : 1 Unit

Transformer capacitance & dissipation factor measuring bridge Specification

  • Voltage Booster Type
  • Compatible with external voltage booster
  • Rated Voltage
  • Typical input 220V 10%, 50Hz or 110V/240V models available
  • Low Voltage
  • Low voltage input for bridge measurement circuit: 12V AC
  • Cooling Type
  • Natural air cooled / no forced cooling required
  • High Voltage
  • Test voltage capability: up to 10kV AC (external high voltage source required)
  • Capacity
  • Measurement range: Capacitance 1pF ~ 200F; Dissipation factor 0~20%
  • Dimension (L*W*H)
  • Approx. 450mm x 320mm x 230mm
  • Operating Temperature
  • -10C to +50C
  • Product Type
  • Capacitance and Dissipation Factor Measuring Bridge
  • Material
  • High grade metal chassis with insulated test terminals
  • Output
  • Capacitance in pF/F; tan and power factor (direct readout or analog indication)
  • Frequency (MHz)
  • 50 Hz / 60 Hz (Mains Frequency); Measurement range typically up to 1 kHz
  • Efficiency
  • High measurement accuracy; Typical error 0.5%
  • Phase
  • Single Phase
  • Usage
  • Measurement of transformer capacitance and dissipation factor (tan delta testing) in high voltage power equipment
  • Coil Structure
  • Non-applicable (instrument does not contain windings)
  • Coil Number
  • Non-applicable
  • Power Scope
  • Operates on AC power supply; suitable for high voltage transformer testing
  • Weight
  • Approximately 12 - 18 kg (varies by model)
  • Power Consumption
  • Approx. 60 VA
  • Measurement Accuracy
  • Tan delta accuracy 0.001, Capacitance accuracy 1% of reading
  • Accessories Provided
  • User manual, calibration certification, test leads, carrying case
  • Calibration
  • Factory calibrated with calibration certificate provided
  • Internal Impedance
  • Optimized for minimal interference and stable bridge operation
  • Display Type
  • Digital panel with LED indicators and analog meter
  • Application
  • Routine and diagnostic insulation tests on power and distribution transformers, bushings, insulators and cables
  • Portable
  • Designed as a transportable benchtop unit with carrying handle
  • Test Object Connection
  • Supplied with shielded high voltage test leads and ground cable
  • Environmental Protection
  • Painted/treated enclosure for indoor laboratory use
  • Safety Features
  • Automatic HV discharge, safety interlock, overcurrent and overvoltage protection
  • Tan Delta Range
  • 0.0001 0.1000
  • Control Interface
  • Rotary selector switch for range and function selection
 

Transformer capacitance & dissipation factor measuring bridge Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 60 Days
 

About Transformer capacitance & dissipation factor measuring bridge

Transformer capacitance & dissipation factor measuring bridge

Description

This different-frequency capacitance & dissipation factor tester is an up-to-date test instrument for measuring capacitance and dissipation factor (dielectric loss and impedance) of various kind of high voltage apparatus full automatically, such as transformers, cables, capacitors, insulators, HV switches, arresters, etc.

This is a high precision instrument; main power is generated by inverter inside and boosted by transformer. Frequency of main power is 45Hz and 55Hz, different to power frequency and so avoid interference by power frequency! It is also suitable for the case that power supply is by generator.

Main features

  • Portable type, very light weight, not more than 30kg
  • Equipped with big screen (240x128mm), menu displaying with relative prompts in the right side, very simple operation, no need special training.
  • Test result can be saved or printed out; One time operation, automatic finish all the test.
  • Equipped with big capacity memory and calendar CMOS chip. Test results can be saved in time/date sequence; History records can be reviewed and printed out at any time.
  • Equipped with wiring diagram menu inside helping operator to wire correctly.
  • Equipped with earth detecting to ensure reliable earthed before being stepped up.
  • By equipped with insulation oil cup, this instrument can also test dielectric loss of insulation oil.
  • Can be suitable for testing full-sealed capacitor type voltage transformer.
  • Inside inverter and sample circuit are all digital control, output voltage is continuous adjustable
  • Equipped with multi-safety protection measures for voltage fluctuation, output short-circuit, over-voltage, over-current, over-temperature, etc.

Main parameters

Service conditions

-5C ~ 40C

RH<80%

Principle of anti-jamming

varying frequency

Power supply

AC220V +/-10% (no limit on frequency)

HV output

voltage

0.5~10kV

precision

5%

Max. current

140mA

Capacity

1000VA

Self-exciting power

AC 0~30V

45Hz/55Hz

Max. current

15A

Resolution ratio

tg 0.001%

Cx: 0.1pF

Precision

tg

+/- (reading x 1.0% + 0.040%)

Cx

+/- (reading x 1.0% +1.0pF)

Measuring range

tg

No limit

Cx

15pF < Cx < 100000pF


10kV

Cx < 30,000pF


5kV

Cx < 60,000pF


1kV

Cx < 100,000pF

For CVT

Cx < 100,000pF

Memory size

Can store 40 units test data

Dimension

470 x 320 x 390mm (L x W x H)

Weight

30kg




Reliable and Accurate Diagnostics

Engineered for high measurement accuracy, this bridge enables professionals to evaluate insulation health in transformers and other power equipment confidently. The direct digital and analog output facilitates quick interpretation of capacitance and dissipation factor results, supporting both routine maintenance and detailed diagnostics.


User-Friendly Portable Design

The portable benchtop build, equipped with a sturdy handle and efficient control interface, allows for effortless transport and operation in laboratory or field environments. All essential accessoriesincluding shielded leads, ground cables, and a user manualpromote straightforward setup and use.


Safety and Versatility Assured

Safety is paramount, with features like automatic high-voltage discharge, safety interlocks, and overcurrent/overvoltage protection. The measuring bridge accommodates a broad range of test samples and is suitable for both AC high voltage and low voltage measurements, compliant with global testing practices.

FAQs of Transformer capacitance & dissipation factor measuring bridge:


Q: How is the transformer capacitance and dissipation factor measuring bridge used in routine testing?

A: It is used by connecting the supplied shielded high voltage test leads to the test objectsuch as a transformer, bushing, or cable. The instrument measures the capacitance and tan delta (dissipation factor), indicating insulation condition for routine and diagnostic maintenance.

Q: What accessories and calibration documentation are provided with the instrument?

A: Each unit comes with a user manual, calibration certificate, shielded test leads, ground cable, and a carrying case, ensuring thorough documentation and essential accessories for operation and compliance.

Q: When should I use this bridge for transformer testing?

A: Deploy the bridge during scheduled maintenance, commissioning, or when deteriorating insulation is suspected. It is also suitable for diagnostic assessments after transformer repairs or in response to abnormal operating conditions.

Q: Where should the measuring bridge be operated for optimal performance?

A: Operate the bridge in indoor laboratory environments, as its enclosure is designed for such conditions. The natural air cooling and rugged construction make it suitable for benchtop or on-site field use with appropriate environmental protection.

Q: What safety features are built into this device?

A: The measuring bridge incorporates automatic high-voltage discharge, safety interlock systems, and overcurrent/overvoltage protection, minimizing electrical hazards during setup and measurement.

Q: How does the digital panel benefit measurement and analysis?

A: The digital display panel, supplemented by LED indicators and an analog meter, offers clear, immediate readings of capacitance and tan delta values, allowing operators to interpret and record results swiftly and accurately.

Q: What is the process of connecting and measuring with the bridge?

A: First, ensure proper grounding using the provided cable. Attach the test leads securely to the object under test. Select the appropriate range and function using the rotary selector, then initiate the measurement. The device displays the results digitally and/or via the analog meter.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transformer Testing Equipment Category

Electrical Silicon Steel Iron Loss Tester

Electrical Silicon Steel Iron Loss Tester

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Low Voltage : 0250V/0500V Adjustable

Rated Voltage : 220V

Voltage Booster Type : Other, Electronic Voltage Booster

Weight : Approx. 18 kg

Partial Discharge Test Equipment For Power Transformer Testing

Partial Discharge Test Equipment For Power Transformer Testing

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Low Voltage : 220 V to 1100 V

Rated Voltage : Up to 100 kV

Voltage Booster Type : Other, Automatic

Weight : Approx. 45 kg 75 kg

Electrical Silicon Steel Iron Loss Tester

Electrical Silicon Steel Iron Loss Tester

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Low Voltage : 0100V Adjustable

Rated Voltage : 220V AC

Voltage Booster Type : Other, Auto Transformer Type

Weight : Approx. 20 kg

Automatic Integrated Test System For Testing Power Transformer

Automatic Integrated Test System For Testing Power Transformer

Price 10000 USD ($) / Set

Minimum Order Quantity : 1 Unit

Low Voltage : Up to 35 kV

Rated Voltage : Up to 330 kV

Voltage Booster Type : Other, Automatic

Weight : Approx. 500 kg