About Transformer capacitance & dissipation factor measuring bridge
Transformer capacitance & dissipation factor measuring bridge
Description
This different-frequency capacitance & dissipation factor tester is an up-to-date test instrument for measuring capacitance and dissipation factor (dielectric loss and impedance) of various kind of high voltage apparatus full automatically, such as transformers, cables, capacitors, insulators, HV switches, arresters, etc.
This is a high precision instrument; main power is generated by inverter inside and boosted by transformer. Frequency of main power is 45Hz and 55Hz, different to power frequency and so avoid interference by power frequency! It is also suitable for the case that power supply is by generator.
Main features
- Portable type, very light weight, not more than 30kg
- Equipped with big screen (240x128mm), menu displaying with relative prompts in the right side, very simple operation, no need special training.
- Test result can be saved or printed out; One time operation, automatic finish all the test.
- Equipped with big capacity memory and calendar CMOS chip. Test results can be saved in time/date sequence; History records can be reviewed and printed out at any time.
- Equipped with wiring diagram menu inside helping operator to wire correctly.
- Equipped with earth detecting to ensure reliable earthed before being stepped up.
- By equipped with insulation oil cup, this instrument can also test dielectric loss of insulation oil.
- Can be suitable for testing full-sealed capacitor type voltage transformer.
- Inside inverter and sample circuit are all digital control, output voltage is continuous adjustable
- Equipped with multi-safety protection measures for voltage fluctuation, output short-circuit, over-voltage, over-current, over-temperature, etc.
Main parameters
| Service conditions | -5C ~ 40C | RH<80% |
| Principle of anti-jamming | varying frequency |
| Power supply | AC220V +/-10% (no limit on frequency) |
| HV output | voltage | 0.5~10kV |
| precision | 5% |
| Max. current | 140mA |
| Capacity | 1000VA |
| Self-exciting power | AC 0~30V | 45Hz/55Hz |
| Max. current | 15A |
| Resolution ratio | tg 0.001% | Cx: 0.1pF |
| Precision | tg | +/- (reading x 1.0% + 0.040%) |
| Cx | +/- (reading x 1.0% +1.0pF) |
| Measuring range | tg | No limit |
| Cx | 15pF < Cx < 100000pF |
| | 10kV | Cx < 30,000pF |
| | 5kV | Cx < 60,000pF |
| | 1kV | Cx < 100,000pF |
| For CVT | Cx < 100,000pF |
| Memory size | Can store 40 units test data |
| Dimension | 470 x 320 x 390mm (L x W x H) |
| Weight | 30kg |
Reliable and Accurate DiagnosticsEngineered for high measurement accuracy, this bridge enables professionals to evaluate insulation health in transformers and other power equipment confidently. The direct digital and analog output facilitates quick interpretation of capacitance and dissipation factor results, supporting both routine maintenance and detailed diagnostics.
User-Friendly Portable DesignThe portable benchtop build, equipped with a sturdy handle and efficient control interface, allows for effortless transport and operation in laboratory or field environments. All essential accessoriesincluding shielded leads, ground cables, and a user manualpromote straightforward setup and use.
Safety and Versatility AssuredSafety is paramount, with features like automatic high-voltage discharge, safety interlocks, and overcurrent/overvoltage protection. The measuring bridge accommodates a broad range of test samples and is suitable for both AC high voltage and low voltage measurements, compliant with global testing practices.
FAQs of Transformer capacitance & dissipation factor measuring bridge:
Q: How is the transformer capacitance and dissipation factor measuring bridge used in routine testing?
A: It is used by connecting the supplied shielded high voltage test leads to the test objectsuch as a transformer, bushing, or cable. The instrument measures the capacitance and tan delta (dissipation factor), indicating insulation condition for routine and diagnostic maintenance.
Q: What accessories and calibration documentation are provided with the instrument?
A: Each unit comes with a user manual, calibration certificate, shielded test leads, ground cable, and a carrying case, ensuring thorough documentation and essential accessories for operation and compliance.
Q: When should I use this bridge for transformer testing?
A: Deploy the bridge during scheduled maintenance, commissioning, or when deteriorating insulation is suspected. It is also suitable for diagnostic assessments after transformer repairs or in response to abnormal operating conditions.
Q: Where should the measuring bridge be operated for optimal performance?
A: Operate the bridge in indoor laboratory environments, as its enclosure is designed for such conditions. The natural air cooling and rugged construction make it suitable for benchtop or on-site field use with appropriate environmental protection.
Q: What safety features are built into this device?
A: The measuring bridge incorporates automatic high-voltage discharge, safety interlock systems, and overcurrent/overvoltage protection, minimizing electrical hazards during setup and measurement.
Q: How does the digital panel benefit measurement and analysis?
A: The digital display panel, supplemented by LED indicators and an analog meter, offers clear, immediate readings of capacitance and tan delta values, allowing operators to interpret and record results swiftly and accurately.
Q: What is the process of connecting and measuring with the bridge?
A: First, ensure proper grounding using the provided cable. Attach the test leads securely to the object under test. Select the appropriate range and function using the rotary selector, then initiate the measurement. The device displays the results digitally and/or via the analog meter.